Product Details:
Type of Cable | Optical Fibre Cable |
Display | Digital |
Description | Fluke Networks DSX-602 |
Weight | 3 lbs (1.36 kg) |
Frequency | 500 MHz |
Quantity Per Pack | 1 |
Calibration Wavelengths | 12,000 Cat 6A with plots |
Technique | 6A Network |
Adapter | 2 - Cat 6A/Class Ea Channel Adapters |
Storage Temperature | -22 Degree F to +140 Degree F (-30 Degree C to +60 Degree C) |
Wire Mapping | Yes |
Brand | Fluke |
Essential Cat 6A and Class EA Copper Certification featuring ten second test times and advanced user interface. Includes channel measurement adapters; Permanent Link adapters also available. Manage jobs and testers from any smart device over Wi-Fi with LinkWare™ Live. Features legendary Fluke Networks reliability backed by worldwide support.
Essential Cat 6A and Class EA Copper Certification featuring ten second test times while meeting industry’s most stringent accuracy requirements. Advanced user interface with gesture-based touchscreen and simplified project management that makes setup fast and foolproof. Built-in diagnostics pinpoint common faults. Includes channel measurement adapters; Permanent Link adapters also available. Upload results directly from the jobsite over Wi-Fi and generate reports with industry standard LinkWare™. Manage jobs and testers from any smart device over Wi-Fi with LinkWare™ Live. Features legendary Fluke Networks ruggedness and reliability backed by worldwide support.
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke Calibration 9171 |
Usage/Application | Industrial Usage |
Material | Stainless Steel |
Features | Metrology Wells feature well depths of 203 mm (8 in) in the Models 9171, 9172, and 9173. The Model |
Brand | Fluke |
Display accuracy
Dry-wells are typically calibrated by inserting a calibrated PRT into one of the wells and making adjustments to the calibrator’s internal control sensor based on the readings from the PRT. This has limited value because the unique characteristics of the reference PRT, which essentially become “calibrated into” the calibrator, are often quite different from the thermometers tested by the calibrator. This is complicated by the presence of significant thermal gradients in the block and inadequate sensor immersion into blocks that are simply too short.
Metrology Wells are different. Temperature gradients, loading effects, and hysteresis have been minimized to make the calibration of the display much more meaningful. We use only traceable, accredited PRTs to calibrate Metrology Wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better than our specs, which range from ±0.1 °C at the most commonly used temperatures to ±0.25 °C at 661 °C.
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke Calibration 9173 |
Usage/Application | Industrial Usage |
Material | Stainless Steel |
Features | Metrology Wells feature well depths of 203 mm (8 in) in the Models 9171, 9172, and 9173. The Model 9 |
Brand | Fluke |
Dry-wells are typically calibrated by inserting a calibrated PRT into one of the wells and making adjustments to the calibrator’s internal control sensor based on the readings from the PRT. This has limited value because the unique characteristics of the reference PRT, which essentially become “calibrated into” the calibrator, are often quite different from the thermometers tested by the calibrator. This is complicated by the presence of significant thermal gradients in the block and inadequate sensor immersion into blocks that are simply too short.
Metrology Wells are different. Temperature gradients, loading effects, and hysteresis have been minimized to make the calibration of the display much more meaningful. We use only traceable, accredited PRTs to calibrate Metrology Wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better than our specs, which range from ±0.1 °C at the most commonly used temperatures to ±0.25 °C at 661 °C.
An application note is available to help better understand the uncertainties mentioned above.
For even better accuracy, Metrology Wells may be ordered with built-in electronics for reading external PRTs with ITS-90 characterizations. (See sidebar, Built in Reference Thermometry)
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke Calibration 9170 |
Usage/Application | Industrial Usage |
Display Type | Digital |
Features | Metrology Wells feature well depths of 203 mm (8 in) in the Models 9171, 9172, and 9173. The Model 9 |
Brand | Fluke |
Display accuracy
Dry-wells are typically calibrated by inserting a calibrated PRT into one of the wells and making adjustments to the calibrator’s internal control sensor based on the readings from the PRT. This has limited value because the unique characteristics of the reference PRT, which essentially become “calibrated into” the calibrator, are often quite different from the thermometers tested by the calibrator. This is complicated by the presence of significant thermal gradients in the block and inadequate sensor immersion into blocks that are simply too short.
Metrology Wells are different. Temperature gradients, loading effects, and hysteresis have been minimized to make the calibration of the display much more meaningful. We use only traceable, accredited PRTs to calibrate Metrology Wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better than our specs, which range from ±0.1 °C at the most commonly used temperatures to ±0.25 °C at 661 °C.
An application note is available to help better understand the uncertainties mentioned above.
For even better accuracy, Metrology Wells may be ordered with built-in electronics for reading external PRTs with ITS-90 characterizations. (See sidebar, Built in Reference Thermometry)
Product Details:
Minimum Order Quantity | 1 Piece |
Accuracy | 0.5% |
Material | Stainless Steel |
Model Name/Number | Fluke 1552a |
Usage/Application | Industrial |
Temperature Range | -10 DegreeC to 50 DegreeC |
Product Details:
Minimum Order Quantity | 1 Piece |
Accuracy | 0.5% |
Material | Stainless Steel |
Model Name/Number | Fluke 1551a |
Usage/Application | Industrial |
Temperature Range | -10 DegreeC to 50 DegreeC |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke 753 |
Display Type | Digital |
Brand | Fluke |
Weight | 1.2 kg |
Size | 136 x 245 x 63 mm |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke 754 Documenting Process |
Display Type | Digital |
Brand | Fluke |
Weight | 1.2 kg |
Size | 136 x 245 x 63 mm |
Product Details:
Minimum Order Quantity | 1 Piece |
Connectivity Type | Bluetooth |
Brand | Fluke |
RAM | 1 GB |
Display Type | LCD |
Compatible With | Android |
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial Use |
Brand | Fluke |
Model Name/Number | Fluke 1770 |
Parameters | More than 500 power quality parameters |
Display Type | LCD |
Operating Temperature | -10 DegreeC to 50 DegreeC |
Power Consumption | 40 VA |
Product Details:
Minimum Order Quantity | 1 Unit |
Model Name/Number | Fluke Calibration 9172 |
Usage/Application | Industrial Usage |
Features | Metrology Wells feature well depths of 203 mm (8 in) in the Models 9171, 9172, and 9173. The Model 9 |
Brand | Fluke |
Dry-wells are typically calibrated by inserting a calibrated PRT into one of the wells and making adjustments to the calibrator’s internal control sensor based on the readings from the PRT. This has limited value because the unique characteristics of the reference PRT, which essentially become “calibrated into” the calibrator, are often quite different from the thermometers tested by the calibrator. This is complicated by the presence of significant thermal gradients in the block and inadequate sensor immersion into blocks that are simply too short.
Metrology Wells are different. Temperature gradients, loading effects, and hysteresis have been minimized to make the calibration of the display much more meaningful. We use only traceable, accredited PRTs to calibrate Metrology Wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better than our specs, which range from ±0.1 °C at the most commonly used temperatures to ±0.25 °C at 661 °C.
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke Calibration 9142 |
Usage/Application | Industrial Usage |
Material | Stainless Steel |
Brand | Fluke |
Built-in features to address large workloads and common applications
Whether you need to calibrate 4-20 mA transmitters or a simple thermostatic switch, a Field Metrology Well is the right tool for the job. With three models covering the range of –25 °C to 660 °C, this family of Metrology Wells calibrates a wide range of sensor types. The optional process version (models 914X-X-P) provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter.
Each process version accepts an ITS-90 reference PRT. The built-in readout accuracy ranges from ±0.01 °C to ±0.07 °C depending on the measured temperature. Reference PRTs for Field Metrology Wells contain individual calibration constants that reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably. The second channel is user-selectable for 2-, 3-, or 4-wire RTDs, thermocouples, or 4-20 mA transmitters. For comparison calibration, don’t hassle with carrying multiple instruments to the field. Field Metrology Wells do it all as a single instrument.
Traditionally, calibrations of temperature transmitters have been performed on the measurement electronics, while the sensor remained uncalibrated. Studies have shown, however, that typically 75% of the error in the transmitter system (transmitter electronics and temperature sensor) is in the sensing element. Thus, it becomes important to calibrate the whole loop—both electronics and sensor.
The process option of Field Metrology Wells makes transmitter loop calibrations easy. The transmitter sensor is placed in the well with the reference PRT and the transmitter electronics are connected to the front panel of the instrument. With 24 V loop power, you are able to power and measure the transmitter current while sourcing and measuring temperature in the Field Metrology Well. This allows for the measurement of as-found and as-left data in one self-contained calibration tool.
All Field Metrology Wells allow for two types of automated thermostatic switch test procedures—auto or manual setup. Auto setup requires the entry of only the nominal switch temperature. With this entry, it will run a 3-cycle calibration procedure and provide final results for the dead band temperature via the display. If you need to customize the ramp rate or run additional cycles, the manual setup allows you to program and run the procedure exactly how you would like. Both methods are fast and easy and make testing temperature switches a virtual joy!
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke 707 |
Display Type | Digital |
Usage/Application | Industrial |
Brand | fluke |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke 719 |
Display Type | Digital |
Usage/Application | Industrial |
Temperature Range | -10 DegreeC to 55 DegreeC |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke 705 |
Display Type | Digital |
Usage/Application | Industrial |
Brand | Fluke |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke 715 |
Display Type | Digital |
Usage/Application | Industrial |
Brand | Fluke |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke 709H |
Display Type | Digital |
Usage/Application | Industrial |
Brand | Fluke |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke Calibration 6102 |
Brand | Fluke |
Weight | 4.5 kg |
Size | 4 mm dia. x 140 mm deep (2.5 x 5.5 in) |
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Model Name/Number | Fluke 120B |
Brand | Fluke |
Accuracy | +- (0.5 % +5 counts) |
Product Details:
Minimum Order Quantity | 1 Piece |
Interface | Quick, guided, graphical setup ensures you're capturing the right data every time, and the intellige |
Memory | Internal flash memory |
Features | s. The thin current probes are designed to easily get through tight conductor spacing and are easily |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke 725 |
Display Type | Digital |
Usage/Application | Industrial |
Temperature Range | -10 DegreeC to 18 DegreeC |
Product Details:
Minimum Order Quantity | 1 Piece |
Accuracy | 0.6% |
Model Name/Number | Fluke Calibration 9009 |
Usage/Application | Industrial |
The Model 9009 includes two independently controlled temperature blocks. The hot block provides temperatures from 50 °C to 350 °C, while the cold block covers the range –15 °C to 110 °C. Each block is controlled by a precision Hart Scientific temperature controller. These aren’t some off-the-shelf controllers we glued into a box. These are Hart Scientific controllers from the leading temperature company in the world.
Each temperature block includes two wells with removable inserts. You can calibrate four probes at once, or you can calibrate two probes at the same time with an external reference (like Hart’s Model 1521 LLK Thermometer), or you can use the two temperature wells to get quick “zero" and “span" references for transmitter calibrations.
Need portability and durability? The 9009 is housed in a tough Pelican™ case that is both airtight and watertight. It’s a small package weighing only 10 pounds, yet it fits everything you need, including a power cord and four extra inserts. Inserts are available to accommodate sensors of any size from 1/16" (1.6 mm) to 7/16" (11.1 mm). This rugged system can go anywhere.
Of course the 9009 also delivers the performance you expect from a Hart Scientific temperature source. The cold block is calibrated to within ±0.2 °C with stability of ±0.05 °C. The hot block’s display is accurate to ±0.6 °C with stability of ±0.05 °C. A NIST-traceable calibration is included for each of the two test blocks.
For use with automated systems, the 9009 comes with an RS-232 connection, which allows you to control and monitor temperatures from your PC. For completely automated calibrations, Hart’s MET/TEMP II software also integrates with the 9009.
Two blocks in one unit, a total range of –15 °C to 350 °C, portability, durability, versatility, performance, automation. Hart Scientific delivers it all.
Product Details:
Model Name/Number | Fluke Calibration 1620A |
Accuracy | +- 0.125 DegreeC over a calibrated range of 16 DegreeC to 24 DegreeC. |
Usage/Application | Industrial |
Temperature Range | +- 0.025 DegreeC for +- 1 Degree changes within 15 DegreeC to 35 DegreeC (+- 0.045 DegreeF for +- 1 Degree changes within 59 DegreeF to 95 |
Weight | 0.7 kg (1.5 lb) |
Display | 240 x 128 graphics monochrome LCD, displays password-protected temperature/humidity data graphically |
The most accurate temperature and humidity graphical data loggers on the market
The DewK measures temperature to ±0.125 °C and humidity to ±1.5% on two channels, and displays it on a big, clear screen. Ethernet, wireless (optional), or RS-232 will allow you to network as many DewKs as you’d like. And the Log Ware III software will allow real-time logging of multiple DewKs, data storage to your computer and seamless integration with MET/CAL® software.
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke Calibration 9103/9140 |
Usage/Application | Industrial Usage |
Brand | Fluke |
These three units beat every other comparable dry-well in the industry in performance, size, weight, convenience, ease of calibration, software, and price. In addition, the heating and cooling rate of each of these dry-wells is adjustable from the front panel, thermal switches can be checked for actuation testing, and multiple-hole inserts are available for a variety of probe sizes.
Hart dry-wells are easy to calibrate. You don't even have to open the case. This means less maintenance costs and less down time when they do need calibration.
Our Interface-it software lets you adjust set-points and ramp rates, log dry-well readings to a file, create an electronic strip chart, and perform thermal switch testing with data collection. The software is written for Windows and has a great graphical interface. Regardless of whether you want basic software or a completely automated calibration system, we've got what you want. Read about all our great packages starting on page 80.
Every dry-well we ship is tested at our factory, and every unit comes with a NIST-traceable calibration. There's no extra charge for the report, because we consider it an essential ingredient in our quality program. You shouldn't have to pay extra for calibration procedures we perform anyway.
Product Details:
Minimum Order Quantity | 1 Piece |
Usage | Industrial |
Brand | Fluke |
Model Name/Number | Fluke Calibration 1523 |
The 1523 Reference Thermometer measures, graphs, and records PRTs, thermocouples, and thermistors. This thermometer readout delivers exceptional accuracy, wide measurement range, logging, and trending, all in a handheld tool you can take anywhere.
The 1523 lets you handle field applications, laboratory measurements, and data logging with ease.
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Fluke 726 |
Display Type | Digital |
Usage/Application | Industrial |
Product Details:
Minimum Order Quantity | 1 Piece |
Display Type | Digital |
Color | Yellow |
Brand | fluke |
Product Details:
Model Name/Number | 707Ex |
Brand | Fluke |
Current measurement Resoultion | 0.001 mA |
Current sourcing Accuracy | 0.015% Rdg + 2 LSD |
Current simulation Range | 0 to 20 mA or 4 to 20 mA |
Current measurement Accuracy | 0.015% Rdg + 2 LSD |
Current sourcing Drive capability | 700 o at 20 mA |
Current simulation Accuracy | 0.015% Rdg + 2 LSD |
Loop power | While measuring mA, 24 V |
Current measurement Range | 0 to 24 mA |
Current sourcing Range | 0 to 20 mA or 4 to 20 mA |
Voltage measurement | Range | 0 to 28 V DC |
Resolution | 1 mV | |
Accuracy | 0.015% Rdg + 2 LSD | |
Environmental Specifications | ||
Operating temperature | -10ºC to 55ºC | |
Storage temperature | -40ºC to 60ºC | |
Humidity (without condensation) | 0 to 95% (0ºC to 30ºC); | |
0 to 75% (30ºC to 40ºC) | ||
0 to 45% (40ºC to 50ºC) | ||
Temperature coefficient | -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC | |
Safety Specifications | ||
Safety | CSA C22.2 No. 1010.1:1992 | |
EMC | EN50082-1:1992 and EN55022:1994 Class B | |
Maximum voltage | 30 V | |
ATEX certification | Ex II G Ex ia IIC T4 Zones 1 and 2, ZELM 02 ATEX 0120 X | |
CE certification | EN61010-1 and EN61326 | |
Mechanical and General Specifications | ||
Size | 152 x 70 x 41 mm | |
Weight | 224 g (350 g including holster) | |
Batteries | One 9V battery Alkaline | |
Warranty | 3 year | |
Shock & vibration | per MIL-T-28800 for a Class 2 Instrument | |
Display current and % of span | Yes | |
Auto step, auto ramp | Yes | |
Span check | Yes |
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Fluke |
Usage/Application | Industrial |
Model Name/Number | SMFT-1000 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
External Field Influence | Complies with DIN 43780 |
Maximum Jaw Opening | Polyester |
Additional Information:
Additional Information:
Product Details:
Model Name/Number | 721Ex |
Brand | Fluke |
Power requirements | 6.0 V DC |
Battery life | >35 hours, typical usage |
Batteries required | (4) Standard AA cells |
Dimensions (H x W x D) | 7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm) |
Weight | 03539 kg (1 lb 3 oz) |
Connectors/ports pressure | Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe |
Altitude | 2,000 m |
Ingress protection | IP-40 |
Pressure calibration and temperature measurement for custody transfer applications
The ideal tool for gas custody transfer applications in potentially explosive atmospheres is the Fluke 721Ex Precision Pressure Calibrator. With dual isolated pressure sensors, it allows you to take simultaneous static and differential pressure measurements with a single tool.
The 721Ex can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).
Electrical and Temperature Measurement 1-Year | |||
Function | Range | Resolution | Accuracy |
mA measure | 0 to 24 mA | 0.001 mA | ±0.015% of rdg ±0.002mA |
Temperature Effect | |||
No effect on accuracy on all functions from 15°C to 35°C | |||
Add ±0.002% F.S./°C for temps outside of 15°C to 35°C | |||
Available Pressure Engineering Units | |||
psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F | |||
Available Pressure Engineering Units | |||
ATEX | Ex ia IIB T3 Gb (Ta= -10… +45 °C) | ||
KEMA 10 ATEX 0168X | |||
IECEx | Ex ia IIB T3 Gb (Ta= -10…+45 °C) | ||
II 2 G IECEx CSA 10.0013X |
Fluke-721Ex-3650 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | |
High pressure sensor | |||
0 psi to +5000 psi, 0.00 bar to 345 bar | 0.1 psi, 0.01 bar | 0.035% of full scale |
Additional Information:
Product Details:
Weight | 65 g (2 1/2 oz.) |
Operating temperature | -20 DegreeC to 60 DegreeC (-4 DegreeF to 140 DegreeF) |
Carrying Case Dimension | 565 mm x 343 mm x 127 mm (22 1/4 in x 13 1/2 in x 5 in) |
Storage temperature | -20 DegreeC to 80 DegreeC (-4 DegreeF to 176 DegreeF) |
Dimensions | 100 mm x 41 mm x 35 mm (4 in x 1 5/8 in x 1 3/8 in) |
Type | 90 Degree roof prism; Accuracy (avg): > 99% |
Model | 830 |
Brand | Fluke |
Weight, including all standard parts | 5.6 kg (12.3 lb) |
Environmental protection | IP 67 (submersible, dustproof) |
Computer | |
CPU | Intel XScale PXA270 running at 312 MHz |
Memory | 64 MB RAM, 64 MB flash |
Display | Type: TFT, transmissive (sunlight-readable), 65,535 colors, backlit LED |
Integrated light sensor for automated adjustment of the brightness to the display according to the lighting conditions which extends battery life | |
Resolution: 320 x 240 pixel; Dimensions: 89 mm (3.5 in) diagonal |
|
Keyboard elements: Setup, measure, diagnose, menu, clear, enter, back keys, navigation cursor cross, alphanumeric keyboard and on/off button | |
LED indicators | Multicolor LED for laser status and alignment condition |
Multicolor LED for battery status | |
Power supply | Integrated Lithium-ion polymer rechargeable battery: 7.4 V/ 2.6 Ah (for optional computer) with typical operating time of 17 hours (based upon an operating cycle of 33% measurement, 33% computation and 33% 'sleep' mode) |
External interface | USB host and USB device (slave) |
Integrated wireless communication, Class 1, transmitting power 100 mW | |
RS232 (serial) for sensor | |
AC adapter/charger socket | |
Environmental protection | IP 65 (dustproof and water spray resistant), shockproof |
Relative humidity 10% to 90% | |
Operating temperature | -10°C to 50°C (14°F to 122°F) |
Storage temperature | -20°C to 60°C (-4°F to 140°F) |
Dimensions | 220 mm x 165 mm x 45 mm (8.7 in x 6.5 in x 1.8 in) |
Weight | 742 g (1.64 lb) |
Sensor | |
Measurement principle | Coaxial, reflected laser beam |
Environmental protection | IP 67 (submersible, dustproof) |
Ambient light protection | Yes |
Storage temperature | -20°C to 80°C (-4°F to 176°F) |
Operating temperature | 0°C to 55°C (32°F to 131°F) |
Dimensions | 107 mm x 70 mm x 49 mm (4 1/4 in x 2 3/4 in x 2 in) |
Weight | 177 g (6 1/2 oz) |
Laser | Type: Ga-Al-As semiconductor laser |
Wavelength (typical) 675 nm (red, visible) | |
Safety class: Class 2, FDA 21 CFR 1000 and 1040 | |
Beam power: < 1 mW | |
Safety precautions: Do not look into laser beam | |
Detector | Measurement area: unlimited, dynamically extendible (U.S. Patent 6,040,903) |
Resolution: 1 μm; Accuracy (avg): > 98% | |
Inclinometer | Measurement range: 0° to 360°; Resolution: < 1° |